Advanced searches left 3/3

Sonography - PubAg

Summarized by Plex Scholar
Last Updated: 15 October 2021

* If you want to update the article please login/register

Contrast-enhanced ultrasound sonography combined with strain elastography to evaluate mandibular lymph nodes in clinically healthy dogs and those with head and neck tumors

Determining lymph node metastases in canines with neoplasia is very important in hosting and creating a therapeutic strategy. There was a considerable distinction in the strain elastographic pattern and lymphosonographic comparison improvement in the metastatic nodes contrasted to medical healthy and balanced or non-metastatic nodes. Mandibular lymph nodes with filling issues after lymphosonography and state-of-the-art pressure elastographic patterns suggested metastasis, and the combination of lymphosonography and strain elastography was valuable for identifying hatred.

Source link: https://pubag.nal.usda.gov/catalog/6852364


The Reliability and Accuracy of Palpation, Radiography, and Sonography for the Detection of Keel Bone Damage

Palpation is the most prominent technique of measuring keel bone damage on live birds, although it has been slammed for being subjective and unreliable. Four evaluators palpated 50 103-week old Lohmann LSL-lite chickens promptly following assisted suicide. Reliability of palpation was examined making use of Cronbach’& rsquo; s Alpha and Fleiss & rsquo; Kappa tests. Radiography and Sonography scores were even more contrasted with dissection scores to identify sensitivity and specificity. First inter-observer dependability was 0. 39 DEV, 0. 53 FR, and 0. 12 TFR, with similar ratings for the 2nd round of palpation. Ratings for intra-observer integrity ranged from 0. 58–-- 0. 79 DEV, 0. 66–-- 0. 90 FR, and 0. 37–-- 0. 87 TFR. Both radiography and sonography showed fairly high level of sensitivity for FR and TFR, yet low for DEV. However, mobile radiography and sonography reveal pledge for detecting keel cracks.

Source link: https://pubag.nal.usda.gov/catalog/6769951


Sonography and sonoelastography in the detection of malignancy in superficial lymph nodes of dogs

HISTORY: The professional applicability of sonography and sonoelastography in the discovery of lymph node hatred in dogs has not been established. PURPOSES: To contrast sonographic and sonoelastographic searchings for between deadly and benign shallow lymph nodes and to examine the analysis efficiency of those techniques. Lymph nodes were categorized as malignant or benign according to cytology or histopathology. Deadly nodes had bigger long axis, brief axis and short‐to‐long axis proportion in comparison with benign nodes. Deadly nodes had a higher frequency of combined vascular distribution on Doppler shade circulation mapping and on power Doppler and higher resistivity index, pulsatility index, and flexibility rating in contrast with benign nodes. CONCLUSIONS AND CLINICAL IMPORTANCE: Results sustain making use of Doppler sonography and SOE as auxiliary methods to illumination mode sonography to discover nodal malignancy.

Source link: https://pubag.nal.usda.gov/catalog/6447049


Sonography of the distal urethra in lambs

Urolithiasis is one of the most common causes of fatality in male lamb and goats, for which sonography is the diagnostic method of choice. Although ultrasound-imaging techniques for kidneys, ureters, and urinary system bladder in tiny ruminants have been defined previously, this research study concentrates on reporting the imaging technique of the extra-pelvic part of the urethra, as virtually all the situations of obstructive urolithiasis result from urinary stones in this part.

Source link: https://pubag.nal.usda.gov/catalog/5724653


Doppler sonography of uterine blood flow at mid‐oestrus during different degree of clinical endometritis in dairy cows

The present study was intended at evaluating the mid‐oestrous uterine blood circulation specifications during differing degree of endometritis in dairy cows. Considerably greater PI and RI were found in cows detected with mild level in contrast with cows detected with modest and severe levels of clinical endometritis. There was considerably greater speed, volume of blood circulation and DPD in both the middle uterine arteries during modest and extreme levels of clinical endometritis as compared to moderate endometritis. Nonetheless, dramatically higher AT was taped in cows diagnosed with moderate level as contrasted to severe and modest levels of clinical endometritis. Pearson's correlation analysis has revealed that RI was favorably associated with PI and AT in all the teams under research.

Source link: https://pubag.nal.usda.gov/catalog/6695937


Veterinary‐focused assessment with sonography for trauma‐airway, breathing, circulation, disability and exposure: a prospective observational study in 64 canine trauma patients

OUTCOMES: Comparison of the results of this new ultrasound method for trauma patients with radiography findings for pneumothorax, pleural effusion, alveolar‐interstitial disorder and stomach effusion revealed favorable contract of 89, 83, 100 and 87% and adverse arrangement of 76, 83, 76 and 92%, respectively. SCIENTIFIC SIGNIFICANCE: The described ultrasound evaluation method can be swiftly done on pets experiencing from trauma throughout resuscitation and it might spot injuries formerly undetectable making use of other veterinary point‐of‐care ultrasound protocols.

Source link: https://pubag.nal.usda.gov/catalog/6316796


The effect of fasting on gastrointestinal motility in healthy dogs as assessed by sonography

Canines were after that fed a 2nd dish after the 24‐hour rapid and ultrasound was repeated 30 minutes later on. One‐way repeated actions ANOVA with blog post hoc Tukey's contrast test was utilized to find statistical differences in time for each and every site analyzed. MAIN and dimensions RESULTS: The mean GI tightening rates in the tummy, duodenum, and jejunum/ileum at T12 and T24 were dramatically less than the GI contraction rates at T30, T3, T6, and T24. 5. The mean GI tightening rates in the belly, duodenum, and jejunum/ileum at T30, T3, T6, and T24. 5 were not statistically various from each various other. VERDICTS: Results of this study show that 2D sonography can be made use of to examine GI motility in pet dogs and that GI tightening rate reduces significantly in the tummy, duodenum, and jejunum/ileum after 12-- 24 hours of fasting.

Source link: https://pubag.nal.usda.gov/catalog/5851974


Transrectal Doppler sonography of uterine blood flow in ewes during pregnancy

In sheep, there is an absence of info on the behavior of hemodynamic indices and parameters of blood flow speed of the uterine artery throughout maternity, making it difficult to establish the actual definition of the values discovered and their possible relevance in regular physiological or pathological states. The purpose of the existing study was to evaluate the blood flow rate criteria and hemodynamic indices of the uterine artery in ewes during maternity. Based on non-invasive colour Doppler sonography, we evaluated the top systolic velocity, end diastolic rate, time-averaged optimum and minimum rate in a heart cycle, pulsatility index, resistance index, systolic/diastolic ratio, heart rate, arterial size and the blood circulation volume. The existing research study is the first to demonstrate changes in uterine hemodynamics throughout maternity in lamb.

Source link: https://pubag.nal.usda.gov/catalog/5603171


Evaluation of the agreement between focused assessment with sonography for trauma (AFAST/TFAST) and computed tomography in dogs and cats with recent trauma

GOAL: To identify the arrangement in between focused assessment with sonography for injury tests and computed tomography for the detection of pleural and peritoneal fluid and pneumothorax in animals that have maintained recent injury. INTERVENTIONS: Abdominal FAST and thoracic FAST tests were done by emergency clinic medical professional or house police officers and radiology house policemans. A kappa fact was calculated to examine for arrangement in between the FAST examinations and CT. MEASUREMENTS AND MAIN RESULTS: The median time to execute all 3 tests was 55 minutes. There was modest to excellent contract between AFAST and CT for discovery of free peritoneal liquid, reasonable to modest agreement between TFAST and CT for discovery of pleural free liquid, and poor arrangement between TFAST and CT for discovery of pneumothorax.

Source link: https://pubag.nal.usda.gov/catalog/6123506

* Please keep in mind that all text is summarized by machine, we do not bear any responsibility, and you should always check original source before taking any actions

* Please keep in mind that all text is summarized by machine, we do not bear any responsibility, and you should always check original source before taking any actions