Advanced searches left 3/3

ARM Cast - Europe PMC

Summarized by Plex Scholar
Last Updated: 12 October 2021

* If you want to update the article please login/register

Effects of Upper Extremity Elevation on Intra-Cast Pressure and Digital Perfusion in a Fiberglass Short-Arm Cast Model.

The goal of this research was to figure out the relationship of digital artery pressure to arm setting and lower arm skin surface pressure utilizing a short-arm cast experimental setup, to identify the best setting for the damaged casted top extremity. Both arm setting and P skin had a substantial effect on P dig, with raising altitude bring about a reduction in P dig. Direct regression evaluation of P skin and P dig with air in the neutral setting produced a modest adverse relationship with body mass index and wrist area, without considerable organization with lower arm size. For volunteers with short-arm fiberglass casts, increasing arm elevation had a big result size on digital arterial pressure, whereas 50 mL simulated swelling had only a little effect size. Decreasing body mass index and forearm area associated with increased skin surface area pressure and decreased digital arterial pressure.

Source link: https://europepmc.org/article/MED/34292830


Automatic Determination of Secondary Dendrite Arm Spacing in AlSi-Cast Microstructures.

A new procedure for the automatic dimension of the second dendrite arm spacing from tiny pictures exists. The individual key and secondary dendrite arms are identified with ideal segmentation methods and gathered as though dendritic structures are gotten suitable for SDAS dimension. An excellent contract in between the automated measurements and the circulation of manual dimensions is found for both cast frameworks thought about.

Source link: https://europepmc.org/article/MED/34070591


Keeping casts dry: A comparison of commercially available cast protectors using a mechanized short arm cast model.

History Upper extremity cracks calling for cast immobilization are exceedingly usual, specifically in the pediatric population. Nevertheless, waterproof cast material is not viable in all scientific settings and damp cast complications remain a source of morbidity and cost. Purposes To figure out if there are differences in the rate and level of moisture exposure for 4 readily available cast guards using a mechanical cast arm version and human volunteers. Approaches A mechanized arm model was created with 4 dental implanted moisture sensors. The top and lower executing cast protectors were then put on 4 adult volunteers prior to thirty mins of swimming. In human subjects testing, 3/4 casts below CVS guards had some degree of wetness-related shade adjustment that would need cast change as contrasted to 0/4 casts below DryPro protectors. Lower-performing products might subject cast-wearers to a raised danger of wet cast issues.

Source link: https://europepmc.org/article/MED/33712298

* Please keep in mind that all text is summarized by machine, we do not bear any responsibility, and you should always check original source before taking any actions

* Please keep in mind that all text is summarized by machine, we do not bear any responsibility, and you should always check original source before taking any actions